Welcome To b2b168.com, Join Free | Sign In
中文(简体) |
中文(繁體) |
Francés |Español |Deutsch |Pусский |
| No.13600061

- Product Categories
- Friendly Links
Information Name: | German original authentic Siemens electric two-way valve VVF31.15-2.5 spot prices |
Published: | 2014-12-24 |
Validity: | 30 |
Specifications: | Original |
Quantity: | 100.00 |
Price Description: | |
Detailed Product Description: | VVF31.15-2.5 original spot VVF31.15-2.5 original spot VVF31.15-2.5 original spot VVF31.15-2.5 100641190 VVF31.15-4 100641191 VVF40.15-1.9 100546434 VVF40.15-2.5 100641214 VVF40.15-3 100546435 VVF40.15-4 100641215 VVF43.100-125 101178042 VVF43.100-160 101178043 VVF43.125-200 101178044 VVF43.125-250 101178045 VVF4*0-315 101178046 VVF4*0-400 101178047 VVF43.65-50 101178018 VVF43 .65-63 101178019 VVF43.80-100 101178041 VVF43.80-80 101178040 VVF47.100 101200590 VVF47.125 101201772 VVF47.150 101200670 VVF47.50 101200582 VVF47.65 101200583 VVF47.80 101200589 VVF529.100K 100326794 VVF529.125K 100326795 VVF529 .150K 100326796 VVF529.50K 100326797 VVF529.65K 100326798 VVF529.80K 100326799 VVF53.100-160 101177988 VVF53.125-250 101177990 VVF5*-0.16 101177916 VVF5*-0.2 101177917 VVF5*-0.25 101177918 VVF5*-0.32 101177919 VVF5*-0.4 101177950 VVF5*-0.5 101177951 VVF5*-0.63 101177952 VVF5*-0.8 101177953 VVF5*0-400 101177991 VVF5*-1 101177954 VVF5*-1.25 101177957 VVF5*-1.6 101177956 VVF53 .15-2 101177958 VVF5*-2.5 101177959 VVF5*-3.2 101177970 VVF5*-4 101177971 VVF53.20-6.3 101177972 VVF53.25-10 101177979 VVF53.25-5 101177973 VVF53.25-6.3 101177974 VVF53.25 -8 101177978 VVF53.32-16 101177977 VVF53.40-12.5 101177980 VVF53.40-16 101177981 VVF53.40-20 101177982 VVF53.40-25 101177983 VVF53.50-31.5 101177984 VVF53.50-40 101177985 VVF53.65-63 101177986 VVF53.80-100 101177987 VVF61.09 100546442 VVF61.10 100546443 VVF61.11 100546444 VVF61.12 100546445 VVF61.13 100546446 VVF61.132 100546447 VVF61.14 100546448 VVF61.142 100546449 VVF61.15 100326801 VVF61.152 100546450 VVF61.23 100331142 VVF61.232 100546451 VVF61.24 100546452 VVF61.242 100546453 VVF61.25 100326802 VVF61.252 100326803 VVF61.39 100326804 VVF61.392 100546454 VVF61.40 100326805 VVF61.402 100326806 VVF61.49 100546455 VVF61.492 100546456 VVF61.50 100326807 VVF61 .502 100326808 VVF61.65 100326809 VVF61.652 100326810 VVF61.80 100326811 VVF61.802 100326812 VVF61.90 100326813 VVF61.902 100326814 VVF61.91 100326815 VVF61.912 100326816 VVF61.92 100326817 VVF61.922 100326818 if necessary, disconnect the execution wiring terminals. Again make sure before using the valve actuator has been installed correctly. Stem sealing gland: is depressurized and cooled in the pipeline, and the case of non-destructive stem surface, you can directly replace the valve stem seals without removing the body, for more information see the "Order" section. If the stem is damaged in the gland, you need to replace the entire stem-plug components. Treatment: Before disposal the valve must be split into various categories of material components. By law, some parts may require special treatment, because these components may cause harm to the environment. RDU20 for heating or cooling system or switch control by PI control room or the return air temperature control heating or cooling output of three automatic heating / cooling changeover Operating modes: normal, energy saving (or off) for remote control installation and control parameters Operating mode switching input can be set to display the room temperature and optional temperature value of the minimum and maximum temperature setpoint limit the use of a single operating voltage AC230V ventilation or air conditioning room temperature control. Can control the following equipment: - Three valve actuators - three damper actuator VVF31.15-2.5 original spot thermostat function via built-in temperature sensor, or obtain the return air temperature sensor temperature by another installation (QAH11.1) , by the output signal of the three actuators to maintain the room temperature set point. PI control thermostat or switch provides control (via DIP2 selection). The proportion of segments or conversion error in heating mode is 2K, cooling mode 1K (adjustable). Integral action time of 5 minutes (adjustable). Automatic switching automatically converted sensor (QAH11.1 + ARG86.3) can be used to measure the water temperature to select from a heating or cooling or heating Go Go cooling conditions. When the water temperature is higher than at 28 ℃ (adjustable), automatically switches to heating mode, when the water temperature is below 16 ℃ and (adjustable), automatically switches to cooling mode. If you just started, the temperature ranged between two transition temperature, the controller will start in heating mode. Conditions will be updated every 30 seconds interval measuring temperature varies. The actual temperature and the operating mode can be viewed by selecting the P14. In the system does not automatically switch, the temperature sensor can be used as an external switch instead of manual switching. If a single heating system, without access to any sensor input, and if it is a single cooling system, the input must be shorted. |
Admin>>>
You are the 5390 visitor
Copyright © GuangDong ICP No. 10089450, Shanghai Mechanical and Electrical Equipment Co., Ltd. Zi Cong All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility
You are the 5390 visitor
Copyright © GuangDong ICP No. 10089450, Shanghai Mechanical and Electrical Equipment Co., Ltd. Zi Cong All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility